品牌
其他厂商性质
上海市所在地
|
型 号 | 转速r/min | 流量m³/h | 压力MPa | 电机kw | 扬程m | 进口mm | 出口mm | 允许颗粒直径mm | 允许维修长度mm |
G20-1 | 960 | 0.8 | 0.6 | 0.75 | 60 | 25 | 25 | 1.5 | 25 |
G25-1 | 960 | 2 | 0.6 | 1.5 | 60 | 32 | 25 | 2 | 30 |
G25-2 | 960 | 2 | 1.2 | 2.2 | 120 | 32 | 25 | 2 | 30 |
G30-1 | 960 | 5 | 0.6 | 2.2 | 60 | 50 | 40 | 2.5 | 35 |
G30-2 | 960 | 5 | 1.2 | 3.0 | 120 | 50 | 40 | 2.5 | 35 |
G35-1 | 960 | 8 | 0.6 | 3.0 | 60 | 65 | 50 | 3 | 40 |
G35-2 | 960 | 8 | 1.2 | 4.0 | 120 | 65 | 50 | 3 | 40 |
G40-1 | 960 | 12 | 0.6 | 4.0 | 60 | 80 | 65 | 3.8 | 45 |
G40-2 | 960 | 12 | 1.2 | 5.5 | 120 | 80 | 65 | 3.8 | 45 |
G50-1 | 960 | 20 | 0.6 | 5.5 | 60 | 100 | 80 | 5 | 50 |
G50-2 | 960 | 20 | 1.2 | 7.5 | 120 | 100 | 80 | 5 | 50 |
G60-1 | 960 | 30 | 0.6 | 11 | 60 | 125 | 100 | 6 | 60 |
G60-2 | 960 | 30 | 1.2 | 15 | 120 | 125 | 100 | 6 | 60 |
G70-1 | 960 | 45 | 0.6 | 15 | 60 | 150 | 125 | 8 | 70 |
G70-2 | 720 | 45 | 1.2 | 18.5 | 120 | 150 | 125 | 8 | 70 |
G85-1 | 720 | 65 | 0.6 | 15 | 60 | 150 | 150 | 10 | 80 |
G105-1 | 500 | 100 | 0.6 | 22 | 60 | 200 | 200 | 15 | 110 |
G135-1 | 400 | 150 | 0.6 | 37 | 60 | 250 | 250 | 20 | 150 |
介质粘度 | 1-1000(CSt) | 1000-10000(CSt) | 10000-100000(CSt) | 100000-1000000(CSt) |
转 速 | 600-1000 | 300-600 | 200-400 | 20-100 |
|
故障 | 原因 | 排除方法 |
1、泵不能起动 | a、新泵转、定子配合过紧 b、电压、电流太低 c、介质粘度过高 | a、用工具人力帮助转动几圈 b、检查、调整 c、稀释料液 |
2、泵不出液 | a、旋转方向不对 b、吸入管路有问题 c、介质粘度过高 d、转、定子损坏或传动部件损坏 e、泵内导物堵塞 | a、调整方向 b、检查泄漏,打开进出口阀门 c、稀释料液 d、检查更换 c、排除更换 |
3、流量达不到 | a、管路泄漏 b、阀门未全部打开或局部堵塞 c、转速太低 d、转、定子磨损 | a、检查修理管路 b、打开全部阀门、排除堵塞物 c、调整转速 d、更换损坏另件 |
4、压力达不到 | a、转子、定子磨损 | a、更换转、定子 |
5、电机过热 | a、电机故障 b、出口压力过高,电机超载 c、定子烧坏或粘在转子上 | a、检查电机、电压、电流、电频 b、检查扬程,开足出口阀门,排除阻塞 c、更换损坏件 |
6、流量压力急剧下降 | a、管道突然堵塞或泄漏 b、定子磨损恶劣 c、液体粘度突然改变 d、电压突然下降 | 参照以下几项,逐项排除 |
7、轴密封处大量泄漏液体 | a、软填料磨损 b、机械密封损坏 | a、压紧或更换填料 |